Specifications:
 

Specifications

 

RO400FC

Control

 

 

 

Type

Microprocessor

 

Languages

English, German, French

 

Temperatures selectable

°C, °F

 

Program capacity

49 (10xpreset standard, 10x preset leadfree, 10xpreset curing, 19xfree)

 

Board counter

optional with sensor or standard with SMEMA option

 

Gas temperature adjustment

Adjustable from 20° to 290°C ( 68° to 554°F) for each zone

Substrate dimensions

 

 

 

Max Reflow width

400 mm

 

Max Substrate width

10-400 mm

 

Max substrate width without middle rail support

400 mm

Conveyor

 

 

 

Transport direction

Left to Right

 

Conveyor speed range

100-800 mm / min see slow speed option for slower speed

 

Conveyor speed repeatability

+/- 2 mm / min

 

Conveyor motor type

24V DC with Encoder

 

In feed length

300 mm

 

Out feed length

200 mm

 

Entrance height (max)

30 mm

 

Free space below substrate

0

Process Dimensions

 

 

 

Heated length

1620 mm

 

Length of Heating zone

400 mm

 

Length of active cooling zone

250 mm

 

Overall length cooling zone

450 mm

Process data

 

 

 

Total air circulation heating zones

2'575 m³/h (1'515 cfm)

 

Air circulation per heating zone

515 m³/h (303 cfm

 

Air circulation peak zone

1'030 m³/h (606 cfm)

 

Air circulation cooling zone

300 m³/h (177 cfm)

Machine Dimensions

 

 

 

Footprint

2'800x914mm (110.2x36")

 

Machine height

1'350 mm (53.2")

 

Weight

660 kg (1455 lb)

Supplies

 

 

 

Electrical

EU: 3x400 VAC, 50Hz, 25 A, circuit breaker not required US: 3x480/277/249/209 VAC, 60Hz, 25 A (with transformer), 3 phase circuit breaker required in front of transformer

 

Power Consumption

5.8 kW continuous, 11.6 kW (during initial heat up,15 min)

 

Minimum exhaust volume

2x150 m3 /h = 300 m3 /h (2x88 cfm=176 cfm)

 

Recommended exhaust volume

2x250 m3 /h = 500 m3 /h (2x150 cfm=300 cfm), option RO400FC-VNT recommended.

 

Filter / air cleaning system

No / must be added in the exhausting system

 

Exhaust specifications

1 each at entry and exit, distance 2.075 meter (81.69”), diameter 150mm (5.9”), length 50 mm (1.97"), gas temperature at exhaust <45°C (<113F)

Enviorment

Noise level

70 dB (A) maximum

Features

Emergency stop buttons

2 (on left and right side of the machine)

 

Main power disconnect

1 with undervoltage circuit breaker

 

Overheat security

Overheat temperature control for each zone (permanent breaker)

 

Safety standards

CE, EN 954-1 Class 3

 

Color

White (RAL9002) silky lustre, fine structure

Temperature profile

Preheat 1

Preheat 2

Preheat 3

Preheat 4

Cooling

Type

Convection

Convection

Convection

Convection

Convection

Max. Gas temp setting

290°C (554°F)

290°C (554°F)

290°C (554°F)

290°C (554°F)

N/A

Heating power

3000W

3000W

3000W

2x3000W

 

Regulation (reflow conditions)

+/- 3°C

+/- 3°C

+/- 3°C

+/- 3°C

 

Ramp times (FR4 inboard measurements)

1.8-2°C /sec

1.8-2°C /sec

1.8-2°C /sec

2-3°C /sec

2.5-3°C /sec

Temperature mesurement

Temperature measurement directly within air stream on PCB height

 

Heating up time from 20 c to set temp 160-160-160-235°C (typical used profile)

9 min

7 min

7 min

18 min

 

ΔT within 400 mm conveyor width

<4°C

<4°C

<4°C

<4°C

 

Cold start warm up to 235°C

21 min

15 min

15 min

18 min

 

Cold start warm up to 290°C

35 min

26 min

26 min

30 min

 

Max temp difference between two adjacent zones

 270°C

 80°C

 80°C

 80°C

 260°C

Blower RPM

2600

2600

2600

2600

2600

Please do not hesitate to contact us for any further information.

Specification Description
Disclaimer 0

Newsletter

Subscribe to our newsletter
Subscribe

Contactgegevens

Fix Trade B.V.
de Schutterij 15
3907 PJ
Veenendaal

0031 (0) 318 544 777
info@fixtrade.nl

© 2021 - 2024 fix-trade | sitemap | rss | ecommerce software - powered by MyOnlineStore